Återgå till huvudnavigering Återgå till sök Gå direkt till huvudinnehållet

Single channel PICOSEC Micromegas detector with improved time resolution

  • A. Utrobicic
  • , R. Aleksan
  • , Y. Angelis
  • , J. Bortfeldt
  • , F. Brunbauer
  • , M. Brunoldi
  • , E. Chatzianagnostou
  • , J. Datta
  • , K. Dehmelt
  • , G. Fanourakis
  • , D. Fiorina
  • , K.J. Floethner
  • , M. Gallinaro
  • , F. Garcia
  • , I. Giomataris
  • , K. Gnanvo
  • , F.J. Iguaz
  • , D. Janssens
  • , A. Kallitsopoulou
  • , M. Kovacic
  • B. Kross, P. Legou, M. Lisowska, J. Liu, M. Lupberger, I. Maniatis, J. McKisson, Y. Meng, H. Muller, E. Oliveri, G. Orlandini, A. Pandey, T. Papaevangelou, M. Pomorski, L. Ropelewski, D. Sampsonidis, L. Scharenberg, T. Schneider, L. Sohl, M. van Stenis, Y. Tsipolitis, S.E. Tzamarias, I. Vai, R. Veenhof, P. Vitulo, X. Wang, S. White, W. Xi , Z. Zhang, Y. Zhou

Forskningsoutput: Tidskriftsbidrag › Artikel › Vetenskaplig › Peer review

Sammanfattning

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.
Originalspråkengelska
Artikelnummer170127
TidskriftNuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
Volym1072
Antal sidor11
ISSN0168-9002
DOI
StatusPublicerad - mars 2025
MoE-publikationstypA1 Tidskriftsartikel-refererad

Vetenskapsgrenar

  • 114 Fysik

Citera det här